Specifications
NIM Bins
 
 
 

Models 556-P and 556H-P
High Voltage Power Supply

 
  • HV supply for use with photomultiplier tubes, microchannel plates, proportional counters, and Geiger-Mueller tubes
  • 0 to ±3 kV
  • 0 to 10 mA
  • Digital meter reads output voltage or current
  • Overload and short-circuited protected
  • External control of output voltage
  • 115 or 230 V AC, 47 to 63 Hz input power

General
The Models 556-P and 556H-P High-Voltage Power Supply provide the noise-free, well-regulated, very stable high voltage necessary for proper operation of photomultipliers, ionization chambers, semiconductor detectors, electron multipliers, and many other devices. The Model 556-P is housed in a double-width NIM module (per DOE/ER-0457T), while the Model 556H-P is a stand-alone unit designed for bench-top operation. The low-noise output is continuously adjustable from ±10 to ±3000 V DC with 0 to 10 mA load current. Noise on the output is <10 mV peak-to-peak, thereby ensuring the highest performance in high-resolution, semiconductor or scintillation spectroscopy systems.

The front-panel digital meter allows visual monitoring of either the output voltage or the output current.

 

The output voltage can be controlled from ±10 to ±3000 V by application of an external input voltage of 0 to ±6.9 V DC. This feature is desirable for control applications and is standard on all units.

The input power for Models 556 and 556H is taken directly from the ac line, either 115 or 230 V AC, 47 to 63 Hz.

Overload and short-circuit protection networks permit operation into short circuits without damage to the instrument.

Output  
Connector Two SHV front-panel connectors wired in parrallel
Polarity Positive or negative, selected by switch on rear panel
Voltage Range 50 to 3000 V; minimum usable voltage 10 V
Current Capacity 0 to 10 mA
Regulation <0.0025% variation in output voltage for combined line and load variations within operating range at constant ambient temperature
Temperature Stability <±50 ppm/°C after 30-minute warm-up; operating range 0 to 50°C.
Long Term Drift <0.01%/hour and <0.03%/24-hour variation in output voltage at constant input line voltage, load, and ambient temperature after 30-minute warm-up.
Ripple <10 mV peak-to-peak, 20 Hz to 20 MHz
Protection Internal circuitry protects against overloads including short circuits.
Resettability Output voltage can be reset to within 0.1%
Controls & Indicators
Power Front-panel toggle switch energizes unit when power cord is connected to appropriate source, and an adjacent red LED lamp indicates when power is applied
Output Voltage One 6-position switch, one 5-position switch, and one 10-turn precision potentiometer; output voltage is the sum of the 3 settings
Meter Front-panel toggle switch selects display of output voltage in V or load current in mA.
Polarity Rear-panel switch selects either positive or negative output polarity
Control Rear-panel locking toggle switch selects the reference source for the output voltage:
INT Selects the internal reference source; the front-panel controls select the output voltage.
EXT Selects the external reference source; output voltage is proportional to magnitude of reference input.
AC Voltage Rear-panel slide switch selects either 115 V or 230 V AC input voltage
LCD Meter Front-panel LCD display indicates output voltage in kV ±10 V or load current in mA ±10 µA. Load current is sum of external load current and internal load current. Internal load resistance is ~5 MW.
Line Input 103–129 V or 206–258 V, 47–63 Hz, 70 W nominal at full output power; supplied through international standard IEC power connector on rear panel. Fuse rating: 1.5 A, 250 V fuse for 115 V AC operation or 0.75 A, 250 V fuse for 230 V AC operation.
Control Voltage Input Full range of output voltage can be based on an external DC reference level applied to  a rear-panel BNC connector; control voltage range is 0 through ±6.9 V DC; control voltage polarity must be the same polarity as that selected by the rear-panel Polarity switch; this input protected against over-voltages >±7 V. Input impedance >45 kW.
Dimensions
Model 556 Standard double-width NIM module, 69 mm x 221 mm (2.7" x 8.714")
Model 556H 114.3 mm high x 224 mm wide x 292 mm deep (4.5" high x 8.8" wide x 11.5" deep)
Weight Model 556 Net: 3.6 kg (8.0 lb); Shipping: 4.5 kg (10.0 lb)
Model 556H Net: 5.7 kg (12.6 lb; Shipping: 6.6 kg (14.6 lb)


SIGNAL RECOVERY is part of Advanced Measurement Technology, Inc, a division of AMETEK, Inc.
 It includes the businesses formerly trading as EG&G Instruments (Signal Recovery),
EG&G Signal Recovery and PerkinElmer Instruments (Signal Recovery)

Copyright© 2008 AMETEK, Inc.  Legal Notices

801 South Illinois Avenue, Oak Ridge, TN 37831-2011, U.S.A. (865) 482-4411 All Rights Reserved.

Ametek logois a trademark of AMETEK, Inc.